The latest from Lubinpla
More stories
-
Safety data sheet retention: how long to keep SDSs on file
Keep a safety data sheet while the chemical is in use; OSHA then requires the sheet or an identity record for 30 years. See the EU and GB rules too.
-
Safety data sheets for non-hazardous chemicals: when required
A non-hazardous chemical needs no SDS under OSHA, but EU rules require one on request for some unclassified mixtures. See the conditions and exemptions.
-
Safety data sheet expiry and update rules by jurisdiction
A safety data sheet has no expiry date, but suppliers must revise it when hazard data change. See the update deadlines under OSHA, REACH and WHMIS rules.
-
Vapor Degreasing: What It Is and How a Vapor Degreaser Works
Vapor degreasing boils a solvent so its vapor condenses on cooler parts, dissolving oil that drips away. How a vapor degreaser works and its settings.
-
Using Diesel as a Concrete Form Release Agent: Conditions
Diesel releases forms but can stain concrete, add bug holes, block coatings and break VOC rules in some areas. When it works, and what to use.
-
ASTM D6200 cooling curves: what they tell you and what they miss
ASTM D6200-21 measures quench oil cooling with an unagitated Inconel 600 probe; it does not predict hardness. See how to read each result and act on it.
-
How to write a baseline monitoring report under 40 CFR 403.12(b)
A baseline monitoring report needs 7 sections, from identification to a compliance schedule. See who files, when, the sampling and why POTWs reject it.
-
How to decide if treated waste coolant can go to the sewer
Before sewering treated coolant, check oil and grease, metals, pH and flashpoint against your POTW permit and 40 CFR 403.5, criterion by criterion.
-
Cooling tower Legionella limits: results that require action
Cooling tower Legionella action starts at any detection in NYC, above 100 CFU/L under UK HSG274 and at 10,000 CFU/L in Quebec. One table of bands.
-
Solvent rub test for powder coating cure: what it shows, misses
ASTM D5402-19(2024) counts the solvent double rubs a coating withstands. It tracks powder cure but does not prove full cure. How to read the results.
Talk to us about your sales team.
Custom plans, custom terms, security reviews and onboarding across teams or branches. Tell us a little about your organization and we will reply with a starting plan.
Contact Sales- 01Start from site data and your documents
Bring in the TDSs, test reports and site records your team already has. Where a case has too little to go on, the agent searches the web for public sources such as manufacturer data and standards.
- 02State the case
Describe the customer's situation in plain words. The agent reads the site's conditions and history, proposes the task that fits, and starts when you say go.
- 03Review the reasoning, step by step
Each step shows what was considered, what the evidence supports and what was ruled out, with the source behind each point. You can carry on, ask for changes or stop.
- 04One document for this customer
The case ends in a document built for that customer: the conclusion, the reasoning, the conditions it depends on and what to do next. Share it through Field Care when you choose.