The latest from Lubinpla
More stories
-
VCI bags: what they are made of and how the inhibitor is built in
VCI bags are polyethylene film with corrosion inhibitor compounded in or coated on, usually 2 to 6 mil. See bag types, thickness and barrier limits.
-
Rust preventive oil: what it is and how it protects stored metal
Rust preventive oil is a temporary oil film with polar inhibitors that stops rust on stored metal. See the five standard types, tests and how it differs.
-
Volatile corrosion inhibitor (VCI): what it is and how it works
A volatile corrosion inhibitor vaporizes inside a closed package and adsorbs on metal as a thin protective layer. See the chemistry, timing and limits.
-
VCI Packaging vs Rust Preventive Oil for Storing Machined Parts
Rust preventive oil suits open, outdoor or handled parts; VCI packaging suits clean, enclosed parts going straight to assembly. Compare them by condition.
-
How to Choose a Rust Preventive for Steel Parts in Storage
Choose thin oils or dry films for short indoor storage, soft films or VCI for longer covered storage, and hard films outdoors. Use the decision table.
-
MIL-PRF-46010 requirements for heat-cured solid film lubricants
MIL-PRF-46010H (2013) requires a heat-cured, corrosion-inhibiting solid film lubricant. See its tests, what to order and how it compares to AS5272.
-
EU microplastics restriction: what it means for PTFE lubricants
Regulation (EU) 2023/2055 keeps PTFE micropowder lubricants for industrial sites on sale, with instructions-for-use and reporting duties. See dates.
-
SCAQMD Rule 1124 2026 amendment: impact on solid film lubricants
South Coast AQMD amended Rule 1124 on April 3, 2026 to phase pCBtF and t-BAc out of aerospace solid film lubricants. See the dates, limits and actions.
-
ISO 4406 standard: what it requires for oil cleanliness codes
ISO 4406:2021 codes particle counts per mL at 4, 6 and 14 µm(c), or 5 and 15 µm by microscope. See what it requires and how to check a lab report.
-
Transformer oil toxicity: a concern only if it contains PCBs
New transformer oil has low acute toxicity; PCB-contaminated oil is regulated and hazardous. Check PCB status, handle it safely and dispose of it legally.
Talk to us about your sales team.
Custom plans, custom terms, security reviews and onboarding across teams or branches. Tell us a little about your organization and we will reply with a starting plan.
Contact Sales- 01Start from site data and your documents
Bring in the TDSs, test reports and site records your team already has. Where a case has too little to go on, the agent searches the web for public sources such as manufacturer data and standards.
- 02State the case
Describe the customer's situation in plain words. The agent reads the site's conditions and history, proposes the task that fits, and starts when you say go.
- 03Review the reasoning, step by step
Each step shows what was considered, what the evidence supports and what was ruled out, with the source behind each point. You can carry on, ask for changes or stop.
- 04One document for this customer
The case ends in a document built for that customer: the conclusion, the reasoning, the conditions it depends on and what to do next. Share it through Field Care when you choose.