Ester Fluid Failure: How a Hydrostatic Pump Loss Was Traced

Summary

In Casey's Fluid Power Journal case (2013), a 300 kW ester hydrostatic drive failed within 12 months because undetected loop overheating oxidized the fluid. The finding holds for this closed-circuit transmission, whose alarm and shutdown temperature sender sat in the reservoir. No loop temperature data were published, so overheating is the investigator's inference.

  • The original pumps on a 300 kW closed-circuit drive running a synthetic ester, biodegradable fluid failed in less than 12 months (Casey, Fluid Power Journal, 2013).

  • The 2013 article reports an acid number of 9.5 mg KOH/g, against an oil change trigger of 4 to 5 mg KOH/g for that fluid (Casey, Fluid Power Journal, 2013).

  • The 2016 retelling of the same case gives an acid number of 10 and 6,500 ppm water, where the 2013 article gives 2,200 ppm (Casey, Power and Motion, 2016).

  • One hydrostatic motor maker applies its temperature limits at the hottest point, normally the motor case drain, with a recommended range of 60 to 85 °C (Danfoss, 2021).

This analysis applies to closed-circuit hydrostatic transmissions with a charge pump and a loop flushing valve running synthetic ester fluid (category HEES). It does not cover open-circuit systems, where return oil passes through the reservoir, and it does not settle where the water in this case came from, which neither published version identifies.

What happened to the ester hydrostatic pump?

The ester hydrostatic pump failed on a 300 kW hydrostatic transmission running a synthetic ester, biodegradable hydraulic fluid: the original set of pumps failed in less than 12 months (Casey, Fluid Power Journal, 2013). Brendan Casey, who ran the failure analysis and reliability audit, judged the circuit adequately designed and well built from an engineering view. Maintenance and reliability, in his view, had plenty of room for improvement.

On site, the oil looked dark in the sight glass, while unused oil was the color of light honey. The existing oil analysis reports showed viscosity increasing. Casey suspected oxidative failure and requested two tests that were not on the original test slate: acid number and water content by Karl Fischer titration.

Internal parts of the failed pumps were heavily coated with a gum-like sludge, which Casey read as evidence that the oil had been polymerizing for some time before the pumps failed. The valve plate and cylinder barrel of both pumps also showed cavitation erosion, which he linked to oxidation through reduced foaming resistance and air release (Casey, Fluid Power Journal, 2013).

The operators reported that the system had never raised a temperature alarm or an overtemperature shutdown. Its temperature sender, alarm levels and shutdowns tested as working. Both the fluid charge and the pumps were written off.

Casey retold the case in a 2016 blog post with different test values; a later section of this article compares the two versions (Casey, Power and Motion, 2016).

What could explain the ester hydrostatic pump failure?

Five candidate causes could explain the ester hydrostatic pump failure. The published evidence points to loop overheating as the main driver, made possible by poor loop flushing, meaning too little hot loop fluid was exchanged with the reservoir. The other three, water hydrolysis, mineral oil carryover and a wrong viscosity grade, each have general evidence behind them, but none fits the oil and the damage as well. The table below sets each candidate against the evidence for and against it, drawn from the two published versions of the case and from field research on biodegradable hydraulic oil:

Candidate cause

Evidence for

Evidence against

Loop overheating oxidized the fluid

Dark oil, rising viscosity (Casey, Fluid Power Journal, 2013), gum-like sludge (Casey, Fluid Power Journal, 2013), acid number 9.5 mg KOH/g against a 4 to 5 mg KOH/g change trigger (Casey, Fluid Power Journal, 2013)

No loop temperature was measured or published; the reservoir sender never alarmed

Flushing valve did not exchange loop fluid with the reservoir

A faulty or misconfigured flushing valve lets the loop overheat while the reservoir stays cool (Casey, Fluid Power Journal, 2013)

Neither version reports an inspection or test of the flushing valve

Hydrolysis from water

Water of 2,200 ppm (Casey, Fluid Power Journal, 2013) or 6,500 ppm (Casey, Power and Motion, 2016), above a 700 ppm rough guide for HEES (Danfoss, 2016)

Ruled out as significant by the lubricant maker's experience (Casey, Fluid Power Journal, 2013); the AIST study cites hydrolysis at a few percent water and found none in field tests where water stayed at 0.1 % or less (Ohkawa et al., AIST, 2019)

Mineral oil carryover

Bio-oil reacting with petroleum oil additives plugged filters in construction machinery (Ohkawa et al., AIST, 2019)

Neither version mentions a changeover from mineral oil or a mixed-fluid test

Wrong viscosity grade

No grade data published; synthetic ester bio-oil already forms a thinner film under pressure than petroleum oil, so a too-low grade would add seizure risk (Ohkawa et al., AIST, 2019)

Viscosity rose in service and the pumps showed sludge and cavitation erosion, not seizure

Loop overheating is the decisive row. The acid number of 9.5 mg KOH/g was roughly double the top of the 4 to 5 mg KOH/g change trigger for that fluid (Casey, Fluid Power Journal, 2013), and the sludge matches polymerized oxidation products. The flushing valve row is not a rival cause but the likely route to the overheating, and water could have added to oxidation without being the main driver (Danfoss, 2016).

Acid number alone cannot separate the two chemical candidates, oxidation and hydrolysis, because hydrolysis of synthetic ester bio-oil also raises the acid value (Ohkawa et al., AIST, 2019). The pattern separates them here: dark color, rising viscosity and gum-like deposits point to oxidative polymerization rather than to hydrolysis.

Two records would have tested the water and carryover rows directly: a hydrolytic stability result for the fluid, or a record of earlier fluid changes and top-ups. Neither version reports one.

What did the ester fluid acid number and water results show?

The ester fluid acid number and water results showed severe oxidation and more water than desirable: 9.5 mg KOH/g and 2,200 ppm in the 2013 report, against a 4 to 5 mg KOH/g oil change trigger for that lubricant (Casey, Fluid Power Journal, 2013).

Acid number counts acidic constituents, including oxidation products formed in service. The current ASTM method states: "It is also sometimes used as a measure of lubricant degradation in service. Any condemning limits must be empirically established." (ASTM International, D664-24, 2024). A condemning limit, the value at which the oil is changed, therefore comes from experience with one fluid. The 4 to 5 mg KOH/g trigger belongs to this fluid only and should not be carried over to another ester or to mineral oil. Neither version of the case names the acid number test method.

Karl Fischer titration measures total water and cannot separate dissolved from free water (Danfoss, 2016). Coulometric Karl Fischer covers water from mg/kg up to percent levels in lubricating oils (ASTM International, D6304-25, 2025).

The 2,200 ppm reading is about three times a 700 ppm critical value that one pump maker gives as a rough guide for HEES fluids (Danfoss, 2016). The AIST study reports no hydrolysis where water entering excavators stays at 0.1 % or less, and cites hydrolysis at a few percent (Ohkawa et al., AIST, 2019), so 2,200 ppm sits between those points. Casey reports that hydrolysis was ruled out as significant on the lubricant maker's experience, not a test.

Both results are single points taken after the failure, so no trend exists.

Why did the ester fluid oxidize so fast in a closed loop?

The ester fluid oxidized fast in the closed loop because the same fluid circulates between pump and motor; without working flushing flow, the loop can overheat while the reservoir stays cool (Casey, Fluid Power Journal, 2013). Motor outlet fluid flows straight to the pump inlet, and a charge pump replaces fluid lost to internal leakage and pressurizes the loop to about 7.6 to 24.8 bar (110 to 360 psi), depending on the transmission maker (Casey, Fluid Power Journal, 2013).

The flushing valve is the exchange point: its purge relief, set approximately 30 psi (about 2 bar) lower than the charge relief valve, vents hot motor outlet fluid to the reservoir (Casey, Fluid Power Journal, 2013). If the valve malfunctions or is set wrongly, there is no positive exchange.

The fluid itself had less margin. Commercial bio-oils made for strict environmental rules have lower oxidation stability than petroleum hydraulic oil, because hindered phenol and aromatic amine antioxidants and zinc dialkyldithiophosphate (ZDTP) cannot be used for aquatic toxicity reasons (Ohkawa et al., AIST, 2019).

Small temperature rises matter, and the hottest metal runs well above the oil. As a rule of thumb, a rise in fluid temperature from 80 °C to 90 °C may cut fluid life by 50 % (Danfoss, 2016), and an axial piston pump cylinder block can run 30 °C or more above the oil, reaching 110 °C at 80 °C oil (Ohkawa et al., AIST, 2019).

Oxidation can then feed itself. Oxidized oil loses foaming resistance and air release (Casey, Fluid Power Journal, 2013), and compressed bubbles create local hot spots that heat the surrounding bio-oil (Ohkawa et al., AIST, 2019). Taken together, the two findings suggest a self-reinforcing cycle.

Why did the reservoir temperature sensor miss the loop oxidation?

The reservoir temperature sensor missed the loop oxidation because, in a closed-circuit hydrostatic transmission, loop fluid flows from the motor outlet directly to the pump inlet without returning to the reservoir (Casey, Fluid Power Journal, 2013). The reservoir sender drove the alarm levels and shutdowns in the programmable logic controller (PLC). It tested as working, yet the operators reported no temperature alarm or shutdown in the life of the system.

Casey's conclusion is direct: in a hydrostatic transmission, the sender on which overtemperature alarms and shutdowns are based belongs in the transmission loop, not the reservoir (Casey, Fluid Power Journal, 2013).

Component maker documentation points the same way. For one series of hydrostatic motors, "The high temperature limits apply at the hottest point in the transmission, which is normally the motor case drain." (Danfoss, 2021). The same document notes that case drain fluid is typically the hottest fluid in the system, and gives a recommended range of 60 to 85 °C and a rated limit of 104 °C at that hottest point (Danfoss, 2021).

The two locations do not conflict: Casey names the loop, the motor maker names the case drain, and neither is the reservoir. When flushing flow is weak, a reservoir reading inside its alarm band says little about loop temperature.

Casey judged the case both a design failure, because a correctly located sender would have prevented it, and a maintenance failure, because oil color and a better test slate could have caught the oxidation earlier (Casey, Fluid Power Journal, 2013, "A Failure of Maintenance or Design?").

Why do the two published versions of the pump failure differ?

The two published versions of the pump failure differ in the acid number, the water content, the order of events (2016 adds that the pumps failed shortly after the fluid) and the depth of the root cause. Neither text explains why (Casey, Fluid Power Journal, 2013; Power and Motion, 2016). The 2016 post on Power and Motion is shorter and retells the case for a maintenance audience, without the circuit analysis. The table below compares the two versions item by item:

Item

2013 Fluid Power Journal

2016 Power and Motion

Acid number

9.5 mg KOH/g (Casey, 2013)

10, unit not stated (Casey, 2016)

Water content

2,200 ppm by Karl Fischer (Casey, 2013)

6,500 ppm, method not stated (Casey, 2016)

Order of events

Fluid oxidized and original pumps failed, both in less than 12 months (Casey, 2013)

Fluid destroyed in under 12 months, pumps shortly after (Casey, 2016)

Oil analysis gap

Acid number and water not on the original test slate

Only particle contamination was being watched

Root cause detail

Reservoir sender, flushing valve, loop overheating

Not described

The largest gap is water: 6,500 ppm in 2016 against 2,200 ppm in 2013 (Casey, Power and Motion, 2016), a difference of about three times that rounding cannot explain. The acid number gap of 9.5 against 10 could be rounding.

Possible explanations, none confirmed, include a second sample taken later after more water entry, or numbers recalled from memory three years on. Neither version gives a sample date.

Both versions agree on the core facts: a 300 kW hydrostatic transmission, a synthetic ester biodegradable fluid, failure inside 12 months and an oil analysis program that missed the oxidation (Casey, Power and Motion, 2016). The conflict is in the numbers and the depth of explanation, not in the story.

For decisions, the 2013 article is the stronger record. It is the earlier and fuller account: it names the water test, gives the change trigger and explains the circuit. Anyone citing the 2016 values should state that the earlier account reports lower figures.

Conclusion and certainty on the oxidation cause

Oxidation as the cause is well supported, loop overheating as the driver is a reasoned inference, and the role of water is unresolved (Casey, Fluid Power Journal, 2013). Sorting each claim by how it is known shows where the case is solid and where it rests on the investigator's judgment.

Confirmed by reported observation or test:

  • The fluid suffered oxidative failure: dark oil, rising viscosity, gum-like sludge on pump parts and an acid number of 9.5 mg KOH/g against a 4 to 5 mg KOH/g trigger (Casey, Fluid Power Journal, 2013).

  • The temperature sender for alarms and shutdowns sat in the reservoir, worked when tested and never alarmed (Casey, Fluid Power Journal, 2013).

  • Both pumps showed cavitation erosion on the valve plate and cylinder barrel (Casey, Fluid Power Journal, 2013).

Inferred from the circuit and the oil:

  • Loop overheating drove the oxidation. Casey states he suspected high-temperature operation, and the circuit logic supports it, but no loop temperature was recorded.

  • A malfunctioning or wrongly configured flushing valve allowed the overheating. The 2013 article presents this as the relevant mechanism, not as a finding from inspecting the valve.

Unconfirmed:

  • Where the water came from, and whether 2,200 or 6,500 ppm is the representative value (Casey, Fluid Power Journal, 2013; Power and Motion, 2016).

  • Whether water contributed to oxidation; hydrolysis was excluded on the lubricant maker's experience, not by a test.

  • Operating hours, so the fluid life cannot be compared with the 3,000 h change interval that one study sets for standard European saturated synthetic ester bio-oils (Ohkawa et al., AIST, 2019).

Action and verification for ester fluid loops

For an ester fluid loop with this failure pattern, action starts at the temperature measurement and ends with a verified oil trend. The case failed through a misplaced sensor and a test slate without oxidation tests (Casey, Fluid Power Journal, 2013, "A Failure of Maintenance or Design?").

  1. Add a temperature sender in the loop or the motor case drain. Alarm against the component maker's limit for the hottest point, for example 60 to 85 °C recommended for one motor series (Danfoss, 2021), or the fluid maker's lower limit for HEES ageing, whichever is lower. To verify, log loop and reservoir temperatures under heavy load; a persistent gap suggests low flushing flow, which you then confirm at the valve.

  2. Check the flushing valve: flow should be present in forward and reverse, and purge relief set below charge relief, approximately 30 psi lower in the case circuit (Casey, Fluid Power Journal, 2013). Do not raise flushing flow beyond the maker's data; excessive motor loop flushing flow may prevent the system from building required pressure in some conditions (Danfoss, 2021).

  3. Add acid number and Karl Fischer water to the test slate and trend both against the fluid maker's limits (Casey, Fluid Power Journal, 2013).

  4. Replace the oxidized fluid. Drain and handle it following the fluid's safety data sheet (SDS) and the used oil rule that applies where you work, such as 40 CFR Part 279 in the US, which defines used oil to include used synthetic oil (US EPA, eCFR, 2026). Drain housings completely to avoid mixing fluid types (Danfoss, 2016).

  5. Find and stop the water entry before refilling.

Lessons as an ester fluid loop checklist

The ester fluid loop case teaches one main lesson: a closed hydrostatic loop needs its own checks for temperature and oil condition, because the reservoir and a particle count can both look normal while the fluid oxidizes (Casey, Fluid Power Journal, 2013; Power and Motion, 2016). The checklist below turns the case into routine checks for any closed-circuit drive running synthetic ester fluid:

Check

Where or how

Act when

Loop temperature

Sender in the loop or motor case drain, not only the reservoir

Above the lower of the component maker's hottest-point limit, 85 °C recommended top for one motor series (Danfoss, 2021), and the fluid maker's limit; one pump maker recommends 30 to 60 °C in normal operation (Danfoss, 2016)

Flushing valve

Flow in forward and reverse; purge relief below charge relief

Purge setting not about 30 psi below charge relief in the case circuit (Casey, Fluid Power Journal, 2013)

Acid number

Trended, method stated on every report; sample every 150 to 200 operating hours (Danfoss, 2016)

Above the fluid maker's limit; 4 to 5 mg KOH/g for the case fluid (Casey, Fluid Power Journal, 2013)

Water

Karl Fischer titration (ASTM D6304)

Above the fluid maker's limit; 700 ppm rough guide for HEES (Danfoss, 2016)

Color and viscosity

Sight glass against new oil; viscosity trend

Darkening or rising viscosity (Casey, Fluid Power Journal, 2013)

The loop temperature row matters most: Casey judged that a sender in the transmission loop would have prevented this failure, which the reservoir sender could not (Casey, Fluid Power Journal, 2013, "A Failure of Maintenance or Design?").

Three further lessons follow. A test slate built around particle counts misses oxidation, so acid number and water belong on it from the first sample. Ester fluids give less margin on temperature than petroleum oil, so the loop limit should be set with the fluid maker, not copied from a mineral oil system. And when you use a published case as evidence, check the earliest full account against later retellings, because the numbers can change.

Lubinpla works cases like this from a customer's own TDS, SDS and site history and returns one cited document for review.