Lubinpla

How to audit whether lubrication routes are being followed

Summary

A lubrication route audit has 4 steps: sample route points, compare the records with the field, check lubricant type and quantity, and trace skipped points. The method fits any manual grease or oil route that leaves a completion record, on paper or in a CMMS, and works the same whether the plant or its lubricant supplier runs the audit.

  • SKF gives a replenishment quantity of Gp = 0.005 x D x B grams for relubrication from the side of a bearing, with D and B in millimetres (SKF, 2018).

  • For relubrication through holes in the centre of the inner or outer ring, the SKF quantity drops to Gp = 0.002 x D x B grams (SKF, 2018).

  • ICML 55.1:2019 sets requirements for a lubrication management system in 12 interrelated areas, written with 45 technical contributors, and its publisher calls it the document a program is audited against (ICML, River Publishers edition 2023).

  • ISO 55001:2024, Edition 2, published in July 2024, specifies requirements for an asset management system (ISO, 2024); ICML 55.1 is written to support it (ICML, 2023).

This audit checks whether existing lubrication routes are carried out as written. It does not set relubrication intervals, judge lubricant selection, audit an oil analysis program or certify a program against ICML 55.1. Automatic lubricators stay in scope only as check points on the route.

What do you need before a lubrication route audit?

Before the audit you need the route list, the completion records for the audit period, the point data behind each route, and permission to stand at the machines while they run. Gather all of it in the office first, so the field walk goes to observing, not searching.

  • The route list for each route in scope: point id, asset, lubricant, quantity, method and frequency. Reliable Media recommends a lube point database that holds frequency, quantity, lubricant type and accessibility notes for every point.

  • Completion records for the period, per route and per point where they exist, showing who signed and when.

  • The lubricant label or color code assigned to each point, and the product data sheet for each lubricant on the list.

  • Grease gun records: which gun serves which grease, and the last measured grams per stroke.

  • Bearing dimensions, from the drawing or the bearing designation, for the points where you will check quantity.

  • Access rules for any point behind a guard: agree with the area owner which guarded points you will view, and view them only with the machine stopped and locked out under the site's lockout/tagout procedure (in the US, OSHA 29 CFR 1910.147).

Before the walk, agree the audit period and the routes in scope with the maintenance owner in writing.

In what order should a sample audit of lube routes run?

A sample audit checks a chosen set of points rather than every point. It runs in 6 steps that cover the 4 parts named at the top, moving from the records to the field and back, so that every field observation ties to a record line. Keep the order: if you walk first, you will notice only what is easy to see.

  1. Pick the sample. Take every point on critical assets, plus a spread of points from each route that includes the tail end of long routes and points that need a ladder or guard removal. The sample size is a judgment call; no source we checked sets one.

  2. Copy the record for each sampled point: last completion date, signer, and the lubricant and quantity as written.

  3. Walk the route in its own order with the route sheet, at the time of day it is normally done.

  4. At each point, record what you see, with a photo: fitting condition, fresh grease at the purge or seal, level or lubricator state, and the label.

  5. On the points chosen for it, check lubricant and quantity with the technician's own gun.

  6. For every gap between record and field, write down the reason given and who gave it, then assign an owner.

Write each observation in the same row as the record it tests, because the audit report later depends on that pairing.

How do you compare lube route completion records with what is on the machine?

To compare completion records with the machine, test each sampled point against six checks, and write what the record says and what you observed in separate columns. A signed route sheet proves that someone signed; it does not prove the grease went in. The table below decides, point by point, whether the record can be trusted and what to do when it cannot.

Audit check

Pass

Fail and what to do

Point is on the route list

Point id on the machine matches a line on the route

Point exists but is on no route: log it and hand it to the route owner to add with a frequency

Record shows completion

Date and signer within the route frequency

Missing or late entry: ask the route owner why, log the reason

Field evidence at the point

Fresh grease at the purge or seal, clean fitting, lubricator level and date current

Old, hardened or no grease, painted-over fitting, empty lubricator: treat the record as unverified

Lubricant matches the label and spec

Gun and container match the point label and the route sheet

Wrong or unlabeled product: stop, check compatibility with the lubricant supplier before more is added

Quantity matches the calculated amount

Strokes x measured g per stroke close to the calculated Gp (SKF, 2018)

Uncalibrated gun or habitual shot count: weigh the gun output, recalculate strokes

Skipped point has a recorded reason

Reason, date and owner written

No reason: count it as a missed point, not a completed one

Field evidence is the row that catches most false completions. A point signed off every week whose fitting is painted over and shows no purge was not greased, whatever the record says.

Keep the two columns honest. Under "record", copy only what the completion entry states: date, signer, and product and quantity if written. Under "observed", write only what you saw or measured at the point on the audit day, with a photo reference.

Do not merge the columns into a single verdict until both are written, because a fail can come from either side. A point greased correctly but never recorded is a records problem; a point recorded but dry is a field problem. The two have different owners.

Where the evidence is unclear, such as a sealed bearing with no visible purge, mark the point "not verifiable in the field" rather than pass or fail, and say so in the report.

How do you check the right lubricant and grease quantity went to each lubrication point?

To check lubricant and quantity, match the product in the technician's gun to the point label, then compare the strokes delivered with a quantity calculated from the bearing size. Both checks need the actual gun, not the route sheet.

For the lubricant, read the gun label, the container and the fitting cap color, then compare them with the route sheet and the product data sheet. One gun per grease type and color coding of the gun and fitting caps make a wrong product visible at a glance (Fabrico, 2026).

For quantity, SKF gives the replenishment quantity for manual relubrication from the side of a bearing as Gp = 0.005 x D x B, in grams, with D the outside diameter and B the total width in millimetres; through holes in the centre of a ring it is 0.002 x D x B (SKF, 2018). In an illustrative case, a bearing with D = 170 mm and B = 39 mm gives Gp = 0.005 x 170 x 39, about 33 g. A gun measured at an illustrative 1.4 g per stroke needs about 24 strokes to deliver it.

Measure the gun: pump 10 strokes onto a scale and divide by 10 (Fabrico, 2026). In one published worked example, three guns in the same plant delivered 0.9, 1.4 and 2.1 g per stroke, so the same "5 shots" ranged from 4.5 to 10.5 g (Fabrico, 2026). A route sheet that counts shots (strokes) without the gun's output cannot pass the quantity check.

Why were lubrication points skipped, and who owns the fix?

Lubrication points are usually skipped for a reason the route design created: a point that needs a ladder or guard removal, a route too long for its time slot, or a point with no tag. The owner of the fix is therefore often the route planner, not the technician. Ask before you judge.

Record the reason in the technician's own words, then sort it:

  • Access: the fitting is behind a guard, at height or painted over. Owner: maintenance planning or engineering, to add an extended grease line, a remote fitting or an automatic lubricator (Fabrico, 2026).

  • Route length: the route takes longer than its slot, so the tail end is cut every time. Owner: the route planner, to split the route.

  • Missing or wrong tag: the point is not identified, so it is on nobody's list. Owner: whoever keeps the lube point database, to tag the point and link it to a route, as Reliable Media recommends.

  • Production conflict: the machine cannot be stopped when the route runs. Owner: production and maintenance together, to agree a window.

  • No named owner: a route assigned to a shift has no single accountable person. Owner: the maintenance manager, to name a person and a deputy.

Every skipped point leaves the audit with one named owner and a date. A deviation with two owners tends to stay open.

How do you report lubrication route audit findings?

Report findings route by route, with what the record says and what was observed in separate columns, and end with an action list that gives every deviation one owner and a date. A plant-wide completion figure hides a single abandoned route inside a good average, so state compliance per route (Fabrico, 2026).

Route compliance in vendor guidance is points completed over points scheduled (Fabrico, 2026); no standard we checked defines it. Report two figures for each route: compliance from the records and compliance confirmed in the field. The gap between them is the audit's main finding.

Label every statement with its source and scope. "Record shows point 14 greased weekly" and "Point 14 fitting painted over, no fresh grease on 23 October 2026" are different kinds of evidence, and the reader should be able to tell them apart. State how many points you sampled, so nobody reads a sample as a full census.

The rules that make a technical service report the customer acts on apply here too: findings first, each with evidence, and each action with an owner and a due date.

Lubinpla's site inspection compares records with field observations, tags each by its source and scope, and issues an action plan with an owner for every deviation.

Frequently asked questions

Can a lubricant supplier run a lubrication route audit?

Yes, if the plant gives access to the completion records and the machines. The supplier brings product knowledge to the lubricant and quantity checks, while the plant owns the routes and most of the fixes. Agree the scope, the routes and the reporting format in writing before the walk.

Does ICML 55.1 tell you how to audit lubrication routes?

No. ICML 55.1 defines what a lubrication program must do across 12 areas, including planned lubrication tasks and inspection, rather than how to do it. The ICML 55.2 guideline covers implementation, with lists of typical requirements an auditor looks for. Separately, ICML has announced an auditing component, ICML 55.3, for certifying programs against all 12 areas.

How do automatic lubricators fit into a lubrication route audit?

Automatic lubricators stay on the route as check points. At each unit, confirm it is present, dispensing and in date, because cartridges run empty and units get knocked off. An empty or expired unit fails the field evidence check, even when the route record shows the stop as done.

How often should a lubrication route audit be repeated?

No source we checked sets an interval. A practical approach is to repeat the audit once the fixes from the last one are closed, and sooner on any route where field-confirmed compliance fell well below the recorded figure, since that gap shows the records cannot be relied on.