Why fish eyes in coating keep coming back after line cleaning

Summary

Fish eyes that return after a coating line cleanup usually come from compressed air, booth supply air, a new coating lot or nearby silicone. A cleanup removes the contamination already on the line but not its source, so the defect returns whenever that source runs again. Map when and where the fisheyes appear before you change anything.

  • Powder spray air should pass an air cooler, a particulate filter (5 micron is suggested), a coalescing filter for oil mist and a final filter before the gun, all inspected regularly (Powder Coated Tough, 2015).

  • Contaminating a standard polyester, epoxy or hybrid powder with a very small amount of silicone or acrylic powder can cause cratering; a spike test at 0.1 percent of the previous powder checks compatibility (Powder Coated Tough, 2015).

  • In one metal decorating plant, fisheyes vanished the day after a search and returned two weeks and one day later, carried in from a nearby dryer stack on an east wind (Circuitnet, undated).

  • ASTM F22-21, the active water-break test, can detect molecular layers of hydrophobic organic contaminants on a cleaned surface (ASTM, 2021).

This answer covers spray-applied liquid coatings and powder coatings on metal parts. It does not cover electrocoat bath contamination, pinholes from substrate outgassing, or defects that appear only after cure, which have other causes. Your coating supplier's data sheet and instructions take precedence for its product.

What are the most likely causes of fisheyes that return after a coating line cleanup?

When fisheyes come back after a cleanup, the likely culprits are five sources the cleanup never reached: compressed air, booth supply air, adjacent silicone, the coating lot and substrate cleaning. Fisheyes form where the coating cannot wet a low surface energy contaminant such as oil, wax, grease or silicone (ArmorPoxy, undated). The wet film will not spread over that spot, so a small dimple opens in the surface.

Compressed air

Compressor lubricant that gets past worn or saturated filters ends up at the gun. One industry article calls unclean compressed air the most prominent cause of craters (Powder Coated Tough, 2015).

Booth supply air and nearby exhaust

Air drawn into the spray room can bring contaminants in from outside. The defect then follows the weather or a neighbor's process, not the line (Circuitnet, undated).

Silicone from adjacent processes and maintenance

Silicone greases, rust preventatives, conveyor lubricants and silicone paints used nearby are listed crater sources (Powder Coated Tough, 2015).

A new coating lot or powder cross-contamination

Contaminants within the powder and cross-contamination from other powders cause craters (ChemQuest, 2025), so the defect can arrive with a new lot.

Substrate cleaning and pretreatment

Forming oils, drawing compounds and press lubricants left on parts cause craters when cleaning or pretreatment drifts (Powder Coated Tough, 2015).

How do you tell compressed air contamination from booth air or coating lot fisheyes?

The pattern separates them: when the fisheyes start, which gun, booth or lot they follow, and where on the part they land. ChemQuest recommends establishing a pattern, such as craters only after a certain powder is run or only with certain equipment, before swapping parts (ChemQuest, 2025). The table below matches each observation on the line to the source it points to.

Check

What you see

Points to

One gun or one air drop

Fisheyes only from that gun or drop

Compressed air at that point, hose or gun

Start date against maintenance

Pattern starts after compressor service or a filter change

Compressed air; lubricant or sealant used in the work

Air at the gun

A clean white cloth held in the air stream from the gun (coating off) shows oil or water spots

Compressed air: filters, dryer or the line downstream

Booth and timing

All booths in one room at once, or only when a nearby process runs

Booth supply air or adjacent silicone

Coating lot

Defect follows a new lot and stops on the old lot

Coating lot or powder cross-contamination

Cleaned part, before coating

Water film breaks on the cleaned surface

Substrate cleaning or pretreatment

The coating lot row settles the most. If fisheyes follow a new lot onto clean, correctly pretreated parts and stop when you go back to the old lot, the source is the coating, not the line. When every booth in one room shows fisheyes at the same time, the shared air becomes the stronger suspect; in one plant the whole room was hit together (Circuitnet, undated). Work through the rows in order. The first two need only the gun records and the maintenance log, not a line stop.

Can silicone from a nearby process cause fisheyes on a coating line?

Yes. Silicone from a nearby process can reach the line through overspray drift, shared supply air, or materials that people and maintenance crews carry in. ChemQuest describes a powder coater whose craters appeared when a neighbor sprayed silicone coatings next door, with the overspray drifting into the finishing area (ChemQuest, undated). In a metal decorating plant, silicone-containing adhesive in a dryer was exhausted through a stack east of the spray room intake. Fisheyes appeared in every booth in that room, but only on an east wind (Circuitnet, undated).

Adjacent sources are easy to miss because they run on someone else's schedule. Release agents, silicone sprays, lubricated conveyors and maintenance greases near the line all belong on the list. Powder Coated Tough advises attention to the materials used to lubricate mechanical equipment and conveyors, and avoiding silicone greases and traditional rust preventatives (Powder Coated Tough, 2015). Personal care products count too: one coater's craters stopped when he stopped using a deodorant, likely because vapors reached the parts while he sprayed with his arm extended (ChemQuest, undated). Map every process within the booth's air path and note which ones ran on the days fisheyes appeared.

Why didn't last time's fisheye fix work on the coating line this time?

There are two possible reasons. The earlier fix may have removed a cause that is not active now, or it cleaned away the contamination without stopping its source. A filter change cures compressed air fisheyes but does nothing for a new coating lot or for silicone in the supply air. A thorough cleanup clears the deposits, and an intermittent source simply puts them back. In one plant the fisheyes were gone by the next day and returned two weeks and one day later in the same spray room (Circuitnet, undated).

Before you reuse a past fix, compare the conditions of both events: which booths and guns, which coating lot, what maintenance happened, what ran nearby and what the weather was. If any of these differ, treat the past cause as a hypothesis to test, not a conclusion. ChemQuest calls craters among the most difficult issues to root-cause because the contamination can come from many sources (ChemQuest, 2025). A defect that looks identical can come from a different place each time. To decide whether a past fix transfers to a new event, see why the same fix did not work this time.

How do you test a coating line for silicone contamination?

Three checks cover it: a water-break test on cleaned parts, a witness panel exposed in the booth, and isolation spraying that removes one variable at a time. In the water-break test, a water film that breaks into beads on a cleaned part points to a hydrophobic, water-repelling film left by cleaning or pretreatment. ASTM F22-21 describes the water-break test as rapid and nondestructive and states it "is not quantitative and is typically restricted to applications where a go/no go evaluation of cleanliness will suffice" (ASTM, 2021). Where a number is needed, ASTM F22-21 points to contact angle methods (ASTM, 2021).

Airborne contamination needs a witness panel. ASTM F22-21 describes exposing a witness surface free of hydrophobic films to the environment and then testing it, with sensitivity depending on the contaminant level and exposure time (ASTM, 2021). Place witness panels at the booth intake and near suspected neighbors.

For the air supply and the coating, ChemQuest recommends systematically changing out equipment such as air filters and hoses (ChemQuest, 2025). A quick first check is to blow gun air, with no coating, onto a clean white cloth and look for oil or water spots. Then spray a known clean panel with a clean gun and hose on the old lot, then the new lot, one change at a time. For powder, Powder Coated Tough advises spiking the powder with 0.1 percent of the previous powder to test compatibility (Powder Coated Tough, 2015).

How do you fix each recurring fisheye cause on the coating line?

Fix each cause at its source and clean afterward; cleaning first only resets the clock. For compressed air, service the air cooler, the particulate and coalescing filters and the final filter at the gun, and drain the compressor and filters. PPG recommends draining and cleaning air filters and compressors regularly and servicing air line filters and driers periodically (PPG, undated). Replace contaminated hoses rather than flushing them.

For booth supply air, move or raise the intake away from the exhaust, or stop the contaminating process. The metal decorating plant separated the intake from the exhaust by raising one of them five feet, about 1.5 m (the account names both the intake vent and the stack), and the problem did not return on the next east wind (Circuitnet, undated). For adjacent silicone, remove the material from the area or substitute it, and approve maintenance greases and sealants before anyone uses them.

For a coating lot, quarantine the lot, return to the previous lot and send retained samples of both to the supplier. Between powder changes, Powder Coated Tough advises strict cleaning protocols to avoid inter-powder contamination (Powder Coated Tough, 2015). For substrate cleaning, restore the cleaner concentration and stage conditions given in the supplier's instructions, follow its safety data sheet (SDS) for handling, and confirm the result with a water-break test. PPG lists a fisheye preventer only as a final effort (PPG, undated).

How do you keep fisheyes from coming back on a coating line?

Two habits keep fisheyes away: control the sources on a schedule, and log every recurrence with its conditions. Start by specifying spray air purity in writing. ISO 8573-1:2010, the current edition, sets purity classes for particles, water and oil in compressed air (AFNOR, ISO 8573-1:2010), so the line can name an oil class and check it. Put filter and air cooler inspection on the maintenance plan, since installing filtration is not enough without regular inspection (Powder Coated Tough, 2015).

Keep a list of approved materials for the finishing area and its air path, including greases, sealants, release agents and personal care products, and require approval for anything new. Run a water-break check on cleaned parts at a fixed frequency (illustrative: once per shift). Keep a retained sample of each coating lot until the parts coated with it are accepted.

The log matters most for recurrence. Record each fisheye event the same way: date and time, booth and gun, coating lot, maintenance in the previous days, processes running nearby, and wind direction where intake air is involved. The metal decorating plant found its source only by matching the defect log against weather records (Circuitnet, undated). With a consistent log, the next recurrence becomes a comparison instead of a fresh search.

When should you call the coating supplier about recurring fisheyes?

Call the coating supplier in three cases: when the defect follows a coating lot, when clean air, clean parts and a known-good lot still give fisheyes, and before you add any fisheye eliminator. A lot-linked defect needs the supplier's batch records and retained samples, and only the supplier can say whether a lot or formulation changed. Send it your pattern log, water-break results, the lot numbers of good and bad runs, and photos of the defect under magnification.

Call a compressed air specialist when fisheyes follow a gun or air drop and filter service does not end them. Ask for an air purity measurement against the ISO 8573-1:2010 oil class your line specifies (AFNOR, ISO 8573-1:2010). Bring in your maintenance and facilities teams when the pattern follows maintenance work or a neighbor's process, since the fix then sits outside the finishing area. Lubinpla's similar case analysis checks, axis by axis, whether a past case's cause and fix carry over to this line's conditions, working from your own records and documents.

Frequently asked questions

Is a crater the same as a fisheye in coating?

Craters and fisheyes both appear as a dimple in the film, but ChemQuest notes that a fisheye has a visible particle at the base of the crater (ChemQuest, 2025). Both come from contaminants with lower surface tension than the coating, so the same source checks apply.

Should you add a fisheye eliminator to stop recurring fisheyes?

Only as a last step. PPG lists a fisheye preventer as a final effort after cleaning and air system maintenance (PPG, undated). An additive hides the symptom while the source keeps running, so find the source first and ask the coating supplier before you add anything.

Can a powder that sat open in the booth cause craters?

It can. ChemQuest asks whether powder packages are left open to ambient air when craters persist after air and equipment changes (ChemQuest, undated). Keep powder containers closed and away from silicone sources.