How do you keep a coolant concentration and pH history per site?
Summary
Keeping a per-site coolant history takes four steps: set one record per sump, note its fluid and target, log dated concentration and pH, review trends. The history works for water-mix metalworking fluids when readings come at a fixed interval, weekly in UK guidance and, for pH, in German rules, and each reading keeps the refractometer factor used.
UK guidance tells employers to measure water-mix fluid concentration with a refractometer, and pH, every week (HSE MW5, 2021).
The same guidance says to keep records of all tests for at least five years, in a table or graph that makes trends easy to spot (HSE MW5, 2021).
In Germany, the pH of used water-mixed coolant is checked weekly, and a sustained drop of more than 0.5 pH units below the freshly mixed fluid is to be avoided (TRGS 611, 2007, section 5.9).
TRGS 611 also sets a weekly nitrite check; above 20 mg/L nitrite the fluid is changed, partly replaced or given an inhibitor agreed with the fluid maker (TRGS 611, 2007, section 5.3).
This method covers water-mix metalworking fluids (soluble oils, semi-synthetics and synthetics) in machine sumps and central systems. Neat cutting oils need a different set of checks. The check intervals quoted come from UK and German guidance; other jurisdictions set their own, and the fluid maker's data sheet sets the target ranges.
Why do scattered coolant readings hide the concentration and pH trend?
Scattered coolant readings hide the concentration and pH trend because a trend needs dated values from the same sump, taken the same way, side by side, and readings kept in notebooks, phone photos and personal spreadsheets rarely share all three. One reading of 6% concentration says little on its own; a run from 7% to 5% over four weekly readings says water is going in faster than concentrate (illustrative figures).
The US OSHA best practices manual describes what a fluid program needs: data on fluid condition, laboratory analyses and additions that "should be tabulated so that relationships and trends in the data can be spotted" (OSHA Metalworking Fluids manual). UK guidance asks for test records in a table or graph for the same reason (HSE MW5, 2021).
For a supplier who services many customer sites, scattered readings have a second cost. When the field engineer who took them moves on, the readings leave with their notebook. The next visit starts from a single reading, and a slow pH decline that began two months earlier cannot be seen.
Which conditions should each coolant record hold?
Each coolant record should hold the identity of one sump and the conditions that make its readings comparable: location, machine and asset reference, fluid product, sump capacity, operating concentration range, operating pH range and refractometer correction factor. These are the header fields of the example monitoring table in the UK guidance on managing fluid quality (HSE MW5, 2021).
Split the record into a fixed header and a reading log:
Header, once per sump: customer, site, machine or central system, asset reference, sump capacity.
Fluid: product name as printed on its data sheet and the date the sump was charged.
Targets: concentration range and pH range from the fluid supplier.
Method: the refractometer factor for that product and the pH method used (strips or meter).
Reading log, every time: measurement date, raw refractometer reading, corrected concentration, pH, who measured, and the action taken.
The refractometer factor belongs in the header because a raw reading is not a concentration. A coolant maker's guidance states that "The real concentration can be calculated by multiplying the refractometer reading in %brix with the refractometer factor" (Blaser Swisslube), and the factor differs by product. Keep the raw reading as well as the corrected value, so a wrong factor can be fixed later.
How do you set up a coolant concentration and pH history step by step?
You set up a coolant concentration and pH history in four steps, done once per sump before the first reading goes in.
Set one record per sump. A central system feeding several machines is one sump; a machine with its own tank is another. Do not merge two sumps into one record, because their trends cancel each other out.
Note the fluid and its targets. Enter the product, the supplier's concentration and pH ranges, and the refractometer factor from the product data sheet. Measure and record the pH of the freshly mixed fluid at the charge date, because German guidance judges a pH drop against the fresh mix (TRGS 611, 2007, section 5.9).
Log dated concentration and pH together. Take the sample from the same point each time, record the raw reading and the corrected concentration, and write the date as YYYY-MM-DD. Wear the gloves and eye protection the fluid's safety data sheet specifies when sampling.
Review the trend before each visit. Compare the latest readings with the target range and with the fresh-mix pH, and note anything moving in one direction.
When the fluid product changes, close the old record and start a new one with a new fresh-mix pH, so readings from two products are not read as one trend.
How often should you check coolant concentration and pH?
You should check coolant concentration and pH at least weekly for water-mix metalworking fluids, the interval in UK guidance and, for pH, in German rules, and more often on a sump that has been unstable. The US OSHA manual sets no fixed interval; it says concentration "must be checked frequently" and asks for a written testing procedure (OSHA Metalworking Fluids manual).
The table below sets the minimum interval for each coolant check by jurisdiction, as written in each source.
Check | Minimum interval |
|---|---|
Concentration (refractometer) | Weekly (HSE MW5, 2021) |
pH | Weekly (HSE MW5, 2021); weekly, monthly for glass and ceramic machining (TRGS 611, 2007, section 5.9) |
Nitrite (Germany) | Weekly; may extend to 4 weeks at most after three consecutive documented readings below 10 mg/L, back to weekly above 10 mg/L (TRGS 611, 2007, section 5.3) |
Appearance and odor | Daily (HSE MW5, 2021) |
Tramp oil, temperature, dipslide | Weekly, tramp oil recommended below 2% (HSE MW5, 2021) |
The pH row is the one to plan around: both UK and German guidance put it at weekly, which is more often than most suppliers visit. Agree with the customer who takes the readings between visits, and record that person's name with each reading. The history stays useful when the same method is used whoever measures.
How do you check a coolant history record?
You check a coolant history record by testing it against five conditions: one record per sump, fluid and targets noted, every reading dated, concentration and pH read together, and an action for each out-of-range reading. A record that fails any of them cannot show a trend you can trust, so fix it at the next visit.
The table below decides whether a per-site coolant record is complete enough to read as a history.
Check | Pass | Fail and what to do |
|---|---|---|
One record per sump | Each record names one machine sump or central system | Two machines in one record: split by asset reference from the next reading on |
Fluid, target and factor | Product name, concentration and pH ranges, refractometer factor in the header | Factor missing: take it from the product data sheet and recalculate stored raw readings |
Each reading dated | Measurement date in YYYY-MM-DD on every line | Undated or visit-week only: ask who measured and when, or mark the line unconfirmed |
Concentration and pH together | Both values on the same date | pH only when there was a problem: add pH to every routine reading |
Out-of-range has an action | Action and re-check result on the same line | Reading outside range with no note: ask the site what was done and record it |
The factor row matters most: a record of raw refractometer readings without the product's factor gives numbers that cannot be compared with the target range. Correcting it once fixes every stored reading, provided the raw values were kept.
How do you read a coolant concentration and pH trend before a site visit?
You read a coolant concentration and pH trend before a site visit by looking at the last four to eight readings for direction, against both the target range and the fresh-mix pH, and by reading concentration and pH as a pair. A single value inside the range can still sit on a falling line.
A coolant maker notes that "The trend of the pH value over a certain period of time gives valuable information" and that a sharp drop "may be caused by a low emulsion concentration or high tramp oil leaking", while contamination with an alkaline cleaner can push pH up (Blaser Swisslube). Reading the pair narrows the cause:
pH and concentration both falling: correct concentration first.
pH falling with concentration on target: likely microbial activity or tramp oil, so look at the dipslide and tramp oil entries. German guidance names an alkaline biocide as a pH measure where microbial attack is heavy (TRGS 611, 2007, section 5.9).
pH rising sharply: ask about cleaners or chemicals entering the sump.
German guidance treats a sustained pH drop of more than 0.5 units below the fresh mix as one to avoid (TRGS 611, 2007, section 5.9), which gives a fixed line to read against. In Lubinpla, a project holds each condition, such as concentration or pH, as values with the date each was measured; there is no trend chart, so you read the history table or ask the agent a question based on that history.
What do you do when a coolant reading is out of range?
When a coolant reading is out of range, you confirm it, correct the fluid by the supplier's procedure, re-measure, and write the action and the new value into the same record line. Skipping the record step leaves the next reader unable to tell a corrected sump from an ignored one.
Confirm the reading. Take a fresh sample, zero the refractometer with clean water, and check that the right factor was applied.
Correct concentration. Water-mix fluids concentrate as water evaporates, so UK guidance says to top up only with fluid below the recommended concentration (HSE MW5, 2021).
Correct pH with the fluid maker. German guidance says the fluid maker should usually be consulted on pH measures (TRGS 611, 2007, section 5.9). Add a biocide only if growth continues after good-practice measures such as concentration, pH and tramp oil are corrected, at the dose the supplier recommends (HSE MW5, 2021), and handle it as its safety data sheet sets out; in the US, use a biocide registered by the EPA for metalworking fluids, as the label allows (OSHA Metalworking Fluids manual).
Act on microbial results. Dipslide results at or above 10^4 cfu/mL indicate microbial growth, and at or above 10^6 cfu/mL call for immediate action, normally draining and cleaning the system (HSE MW5, 2021).
Re-measure and record. Note the action, who did it and the re-check value on the same date.
Common mistakes in coolant record keeping
Coolant record keeping goes wrong in a few repeatable ways, and storing raw refractometer readings with no factor is the one that breaks every comparison with the target range once the product or the person measuring changes. Five more mistakes undermine the history:
Recording the visit date instead of the measurement date, so readings taken by site staff between visits pile up on one day.
Keeping two sumps in one record, so a rising sump and a falling sump average out to a flat line.
Measuring pH only when something smells or rusts, which leaves no baseline to compare against.
Changing fluid product without starting a new record and a new fresh-mix pH.
Writing "adjusted" with no amount, which hides how much concentrate or water went in and makes the next reading hard to interpret.
Each of these is cheap to avoid at the moment of entry and expensive to repair later, because the person who took the reading may no longer remember the details.
Frequently asked questions
Is there a ready-made coolant record template?
UK guidance includes an example table and graph with header fields for location, machine, product, ranges and refractometer factor (HSE MW5, 2021). The Institute for Occupational Safety and Health of the German Social Accident Insurance offers a coolant monitoring sheet as an Excel file on its coolant portal, and notes that the portal is under revision (DGUV IFA). Adapt either to one record per sump.
Are pH test strips good enough for a trend?
Test strips can give a usable weekly trend if the same strip type is used each time. A coolant maker notes that strips need no calibration but must not be used past their expiry date (Blaser Swisslube). Record the method, and do not mix strip and meter readings in one trend.
Should the customer or the supplier take the readings?
Either can, as long as the method, the sample point and the record are the same. Weekly checks usually fall to site staff, with the supplier reviewing the record at each visit. UK guidance says that when a third party does the checks, the employer should review the results and the actions taken (HSE MW5, 2021).