Process & Utility Chemicals
Process & Utility Chemicals covers the chemicals that run plant utilities and production processes: cooling and boiler water, wastewater treatment, heat transfer fluids, quenching in heat treatment and mold release.
Cooling tower water treatment
-
Why a PTSA tracer reads low when the chemical pump is dosing
A low PTSA tracer reading with a running pump usually means product is not reaching the tower, blowdown rose, or the fluorometer reading is suppressed.
-
Cooling tower conductivity: controller vs handheld meter readings
A cooling tower controller and handheld meter disagree from probe fouling, calibration drift or temperature compensation. How to tell which is right.
-
Why white rust comes back after cooling tower passivation
White rust that returns after passivation usually means the first passivation was incomplete or pH, alkalinity or hardness drifted. Tell which, and act.
-
Cooling tower acid overfeed crashed the pH: what to do now
After a cooling tower acid overfeed, stop the acid feed, raise blowdown, check metals and discharge limits, fix the controller and confirm recovery.
-
Bleach to chlorine dioxide in cooling towers: switching risks
Chlorine dioxide beats bleach in alkaline or ammonia-laden cooling water, but generator choice, chloride, copper and acid supply can trip a switch.
-
How to show a water treatment chemical caused the results
To credit a water treatment chemical, fix a baseline, match periods, adjust for cycles, makeup water and load, rule out cleaning, then credit the rest.
-
Annual water treatment service review: what it should cover
An annual water treatment service review fixes the period and systems, compares each result with its control limit, lists open risks and sets next checks.
-
KPIs to agree in a water treatment service contract
Agree outcome KPIs such as control-range compliance and corrosion rate when the supplier controls dosing, and visit and reporting KPIs when the plant does.
-
What a water treatment proposal to a plant should include
A water treatment proposal to a plant should state current condition, control targets and ranges, chemicals and feed, tests, reporting and plant duties.
-
Why cooling tower cycles of concentration drop: control or makeup
Cooling tower cycles usually drop from excess blowdown, a drifting conductivity controller, a makeup change or leaks. Compare ion cycles to find which.
-
ASHRAE 188 records: what the owner and the vendor each keep
ASHRAE 188 puts program records with the building owner's team. See which records the water treatment vendor produces and where each one is kept.
-
Cooling tower log sheet: what to record and what to read together
Record pH, conductivity, alkalinity, calcium hardness, oxidant residual and makeup at each cooling tower visit, then read them in pairs to catch drift.
-
How to verify a cooling tower biocide program is working
Verify a cooling tower biocide program with oxidant logs, HPC and Legionella against NYC Chapter 8 limits, ATP against baseline, and a fixed sample plan.
-
Non-phosphorus cooling tower treatment: risks to check first
Before a cooling tower goes phosphorus-free, check galvanized white rust, steel protection, sulfate and iron in makeup water, biology and discharge.
-
Cooling tower chemical dosing: how to check the inhibitor dose
Expected cooling tower inhibitor use equals makeup divided by cycles, times the target dose. Compare it with actual drum use and see what a gap points to.
-
Why cooling water treatment chemical usage rises: how to answer
Cooling water chemical usage rises with more makeup, lower cycles, new water quality, leaks or feed errors; check records before answering the customer.
-
Cooling tower Legionella limits: results that require action
Cooling tower Legionella action starts at any detection in NYC, above 100 CFU/L under UK HSG274 and at 10,000 CFU/L in Quebec. One table of bands.
Boiler water treatment and RO
-
Boiler water additives for food-contact steam: 21 CFR 173.310
21 CFR 173.310 allows only listed boiler water additives in food-contact steam, within set limits. See how to check each ingredient and who decides.
-
How to plan a boiler water treatment program changeover
Fix baseline values, sample feedwater, boiler water and condensate more often, set stop signals, then switch dosing in stages and retune blowdown.
-
Switching a boiler to filming amines: risks and failure modes
Switching a boiler to filming amines mostly fails through loosened deposits, overfeed at start-up and testing in the wrong stream. How to spot each one.
-
How to run an RO antiscalant trial with normalized flow
Log a baseline, normalize permeate flow and differential pressure, step the antiscalant dose and stop on preset limits before the RO membranes scale up.
-
How to Choose an RO Antiscalant for High Silica Feed Water
Pick an RO antiscalant whose silica rating covers the projected reject silica at your pH and temperature, and control iron and aluminum first.
-
How to tell if a boiler water treatment program is working
Judge a boiler water treatment program by results, not control tests: feedwater hardness, condensate iron, deposits and tube condition against set limits.
Industrial wastewater treatment chemicals
-
Why a flocculant works in the jar test but not in the plant
A flocculant that passes the jar test but fails in the plant usually points to mixing, polymer makedown, dose point or raw water drift. What to check.
-
How to write a baseline monitoring report under 40 CFR 403.12(b)
A baseline monitoring report needs 7 sections, from identification to a compliance schedule. See who files, when, the sampling and why POTWs reject it.
-
How to decide if treated waste coolant can go to the sewer
Before sewering treated coolant, check oil and grease, metals, pH and flashpoint against your POTW permit and 40 CFR 403.5, criterion by criterion.
Heat transfer fluids and glycol systems
-
Make-up water in a closed loop: when the volume is too high
A closed loop should need almost no make-up water. Set a baseline after filling, then read the meter with inhibitor and conductivity to confirm a leak.
-
Mixing two brands of inhibited glycol in a chiller loop
Only if both makers confirm the same glycol base and compatible inhibitors and a jar mix stays clear. Otherwise drain, flush and refill the chiller loop.
-
High temperature heat transfer oil at 300C: mineral vs synthetic
At 300 C a mineral heat transfer oil works only in a closed or nitrogen-blanketed system; open tanks and high film temperature call for a synthetic fluid.
-
Closed Loop Water Treatment Log Sheet With Ranges and Actions
A closed loop water treatment log sheet that writes the range before each result, ties it to sample point and method, and names the action. Free Excel log.
-
Heat transfer fluid: what it is and how industry uses it
A heat transfer fluid carries heat between a heater or chiller and process equipment in a closed loop. See the main types and the temperature range each.
-
How to Measure Glycol Concentration in a Chiller or HVAC Loop
Measure chiller loop glycol concentration in four steps: circulate, sample, read a refractometer with the right glycol scale, then check the freeze point.
-
How to Write a Closed Loop Water Treatment Report Owners Act On
A closed loop water treatment report needs sampling details, results against limits, trends, a diagnosis and owned actions. Structure and a checklist.
-
Replace or Re-Inhibit Loop Glycol: How to Decide From Fluid Tests
Decide whether to replace or re-inhibit closed loop glycol by checking reserve alkalinity, pH, glycol percent, metals and microbes against supplier limits.
Quenching oils and heat treatment
-
How to plan a changeover trial when changing quench oil
Fix cooling curves for used and new oil, run the same reference parts for hardness and distortion, clean the tank, check flash point and set stop rules.
-
Quench oil analysis results that mean the oil needs attention
Quench oil needs attention when viscosity, acid number, water or the cooling curve drift from its new-oil baseline. Read each result with part hardness.
-
ASTM D6200 cooling curves: what they tell you and what they miss
ASTM D6200-21 measures quench oil cooling with an unagitated Inconel 600 probe; it does not predict hardness. See how to read each result and act on it.
Mold release agents and die lubricants
-
Using Diesel as a Concrete Form Release Agent: Conditions
Diesel releases forms but can stain concrete, add bug holes, block coatings and break VOC rules in some areas. When it works, and what to use.